5.3減速器的傳(chuán)動(dòng)效率η見表11。
|
公稱
傳動比
i
|
輸入轉速
n1
r/min
|
中心距,mm
|
|
80
|
100
|
125
|
140
|
160
|
180
|
200
|
225
|
250
|
280~710
|
|
傳動功率η%
|
|
10
|
1500
|
90
|
91
|
91
|
92
|
92
|
93
|
93
|
94
|
94
|
95
|
|
1000
|
90
|
91
|
91
|
92
|
92
|
93
|
93
|
94
|
94
|
95
|
|
750
|
89
|
89.5
|
90
|
91
|
91
|
92
|
92
|
93
|
93
|
94
|
|
500
|
87
|
87.5
|
88
|
89
|
89
|
90
|
90
|
91
|
91
|
92
|
|
12.5
|
1500
|
89
|
90
|
90
|
91
|
91
|
92.5
|
92.5
|
93.5
|
93.5
|
94.5
|
|
1000
|
89
|
90
|
90
|
91
|
91
|
92.5
|
92.5
|
93.5
|
93.5
|
94.5
|
|
750
|
88
|
88.5
|
89
|
90
|
90
|
91.5
|
91.5
|
92
|
92
|
93
|
|
500
|
86
|
86.5
|
87
|
88
|
88
|
89
|
89
|
90
|
90
|
91
|
|
14
|
1500
|
88.5
|
89.5
|
89.5
|
91
|
91
|
92
|
92
|
93
|
93
|
94
|
|
1000
|
88.5
|
89.5
|
89.5
|
91
|
91
|
92
|
92
|
93
|
93
|
94
|
|
750
|
87
|
88
|
88.5
|
89.5
|
89.5
|
91
|
91
|
91.5
|
91.5
|
92.5
|
|
500
|
85
|
86
|
86.5
|
87.5
|
87.5
|
88
|
88
|
89
|
89
|
90
|
|
16
|
1500
|
88
|
89
|
89
|
90
|
90
|
91
|
91
|
92
|
92
|
93
|
|
1000
|
88
|
89
|
89
|
90
|
90
|
91
|
91
|
92
|
92
|
93
|
|
750
|
86.5
|
87
|
88
|
89
|
89
|
90
|
90
|
91
|
91
|
92
|
|
500
|
84
|
84.5
|
85
|
86
|
86
|
87
|
87
|
88
|
88
|
89
|
|
18
|
1500
|
87.5
|
88
|
88
|
89.5
|
89.5
|
90
|
90
|
91
|
91
|
92
|
|
1000
|
87
|
88
|
88
|
89
|
89
|
90
|
90
|
91
|
91
|
92
|
|
750
|
85.5
|
86
|
87
|
88
|
88
|
89.5
|
89.5
|
90
|
90
|
91
|
|
500
|
83
|
83.5
|
84
|
85
|
85
|
86
|
86
|
87
|
87
|
88
|
|
20
|
1500
|
86.5
|
87
|
87
|
88
|
88
|
89.5
|
89.5
|
90
|
90
|
91
|
|
1000
|
86
|
86.5
|
87
|
88
|
88
|
89.5
|
89.5
|
90
|
90
|
91
|
|
750
|
84.5
|
85
|
86
|
87
|
87
|
89
|
89
|
89.5
|
89.5
|
90
|
|
500
|
82
|
82.5
|
83
|
84
|
84
|
85
|
85
|
86
|
86
|
87
|
|
22.4
|
1500
|
85.5
|
86
|
86
|
87
|
87
|
88.5
|
88.5
|
89
|
89
|
90
|
|
1000
|
85
|
86
|
86
|
87
|
87
|
88.5
|
88.5
|
89
|
89
|
90
|
|
750
|
83.5
|
84.5
|
84.5
|
85.5
|
85.5
|
87.5
|
87.5
|
88
|
88
|
89
|
|
500
|
80.5
|
81
|
81
|
82
|
82
|
83
|
83
|
84
|
84
|
85.5
|
|
25
|
1500
|
85
|
86
|
86
|
87
|
87
|
88
|
88
|
88.5
|
88.5
|
89
|
|
1000
|
84
|
85
|
86
|
87
|
87
|
88
|
88
|
88.5
|
88.5
|
89
|
|
750
|
83
|
83.5
|
84
|
85
|
85
|
86
|
86
|
87
|
87
|
88
|
|
500
|
79
|
79.5
|
80
|
81
|
81
|
81.5
|
81.5
|
83
|
84
|
85
|
|
28
|
1500
|
82.5
|
83
|
83.5
|
84
|
84
|
85
|
85
|
86
|
86
|
87.5
|
|
1000
|
82
|
82.5
|
83
|
84
|
84
|
85
|
85
|
86
|
86
|
87.5
|
|
750
|
81
|
81.5
|
82
|
83
|
83
|
84
|
84
|
85
|
85
|
86
|
|
500
|
77
|
77.5
|
77.5
|
78
|
78
|
79
|
79
|
80
|
80
|
81.5
|
|
31.5
|
1500
|
80
|
80.5
|
81
|
82
|
82
|
83
|
83
|
84
|
84
|
85
|
|
1000
|
80
|
80.5
|
81
|
82
|
82
|
83
|
83
|
84
|
84
|
85
|
|
750
|
79
|
79.5
|
80
|
81
|
81
|
82
|
82
|
83
|
83
|
84
|
|
500
|
75
|
75.5
|
76
|
76.5
|
76.5
|
77
|
77
|
78
|
78
|
79
|
|
35.5
|
1500
|
78.5
|
79
|
79.5
|
80
|
80
|
81
|
81
|
82
|
82
|
83.5
|
|
1000
|
78.5
|
79
|
79.5
|
80
|
80
|
81
|
81
|
82
|
82
|
83.5
|
|
750
|
77
|
77.5
|
78
|
79
|
79
|
80
|
80
|
81
|
81
|
82
|
|
500
|
73
|
73.5
|
74
|
74.5
|
74.5
|
75.5
|
75.5
|
76
|
76
|
77.5
|
|
40
|
1500
|
76
|
76.5
|
77
|
78
|
78
|
79
|
79
|
80
|
80
|
81
|
|
1000
|
76
|
76.5
|
77
|
78
|
78
|
79
|
79
|
80
|
80
|
81
|
|
750
|
75
|
75.5
|
76
|
77
|
77
|
78
|
78
|
79
|
79
|
80
|
|
500 |
71
|
71.5
|
72
|
73
|
73
|
74
|
74
|
75
|
75
|
76
|
|
45
|
1500
|
74.5
|
75
|
76
|
77
|
77
|
78
|
78
|
79
|
79
|
80
|
|
1000
|
74.5
|
75
|
76
|
77
|
77
|
78
|
78
|
79
|
79
|
80
|
|
750
|
73.5
|
74
|
74.5
|
75
|
75
|
76
|
76
|
76.5
|
76.5
|
77
|
|
500
|
69.5
|
70
|
70.5
|
71.5
|
71.5
|
72.5
|
72.5
|
73
|
73
|
74.5
|
|
50
|
1500
|
73
|
74
|
74
|
75
|
75
|
76
|
76
|
77
|
77
|
78
|
|
1000
|
73
|
74
|
74
|
75
|
75
|
76
|
76
|
77
|
77
|
78
|
|
750
|
72
|
72.5
|
73
|
74
|
74
|
75
|
75
|
76
|
76
|
77
|
|
500
|
68
|
68.5
|
69
|
70
|
70
|
71
|
71
|
72
|
72
|
73
|
|
56
|
1500
|
71.5
|
72.5
|
72.5
|
73.5
|
73.5
|
74.5
|
74.5
|
75
|
76
|
77
|
|
1000
|
71.5
|
72.5
|
72.5
|
73.5
|
73.5
|
74.5
|
74.5
|
75
|
76
|
77
|
|
750
|
70.5
|
71
|
71.5
|
72.5
|
72.5
|
73.5
|
73.5
|
74.5
|
74.5
|
75.5
|
|
500
|
67
|
67.5
|
68
|
68.5
|
68.5
|
69.5
|
69.5
|
71
|
71
|
71.5
|
|
63
|
1500
|
70
|
71
|
71
|
72
|
72
|
73
|
73
|
74
|
74
|
75
|
|
1000
|
70
|
71
|
71
|
72
|
72
|
73
|
73
|
74
|
74
|
75
|
|
750
|
69
|
69.5
|
70
|
71
|
71
|
72
|
72
|
73
|
73
|
74
|
|
500
|
65
|
65.5
|
66
|
67
|
67
|
68
|
68
|
69
|
69
|
70
|
附錄A
減速器的選用方法
(參考件)
A1減速器的選用條件
選用減速器應知原動(dòng)機、工作機類型及載荷性質,每日平均運轉時間,啓動(dòng)頻率和環(huán)境溫度。
A2減速器的選用方法
A2.1表9國的額定輸入功率P1及額定輸出轉矩T2适用於減速器工作載荷平穩,每日工作8h,每小時啓動次數不大於10次,啓動轉矩爲額定轉矩的2.5倍,小時負荷率JC=100%,環境溫度爲20℃。
其他工作狀态的減速器額定輸入功率P1及額定輸出轉矩T2可按表9選取,用工作狀況系數(見表A1~表A5)進行修正。
A2.2計算輸入功率P1或計算輸出轉矩T2
機械功率P1≥P1WKAK1
或T2≥T2WKAK1
熱功率P1≥P1WK2K3K4
或T2≥T2WK2K3K4
式中:P1W——減速器實際輸入功率,KW;
T2W——減速器實際輸出轉矩,N·m;
KA——使用系數,見表A1;
K1——啓動頻率系數,見表A2;
K2——小時負荷率系數,見表A3;
K3——環境溫度系數,見表A4;
K4——冷卻方式系數,見表A5;
A2.3在下列間(jiān)歇工作中可不校驗輸入熱(rè)功率
a.在1h内多次起動並(bìng)且運轉時間總和不超過20min的場(chǎng)合。
b.在一個工作周期内運轉時間不超過40min並(bìng)且間隔2h以上起動一次的場(chǎng)合。
A2.4實際輸入功率超過許用輸入熱功率,則須採(cǎi)用強制冷卻措施或選用更大規(guī)格的減速器。
表A1
|
原動機
|
載荷性質(工
作機特均勻性)
|
每日工作時間,h
|
|
≤0.5
|
>0.5~1
|
>1~2
|
>2~10
|
>10
|
|
KA
|
|
電動機、汽輪機燃氣輪機
(起動(dòng)轉矩小,偶爾(ěr)作用)
|
均勻
|
0.6
|
0.7
|
0.9
|
1
|
1.2
|
|
輕度沖擊
|
0.8
|
0.9
|
1.0
|
1.2
|
1.3
|
|
中等沖擊
|
0.9
|
1.0
|
1.2
|
1.3
|
1.5
|
|
強烈沖擊
|
1.1
|
1.2
|
1.3
|
1.5
|
1.75
|
|
汽輪機、燃汽輪機、液動(dòng)機或電(diàn)動(dòng)機
(起動(dòng)轉矩大,經(jīng)常作用)
|
均勻
|
0.7
|
0.8
|
1
|
1.1
|
1.3
|
|
輕度沖擊
|
0.9
|
1
|
1.1
|
1.3
|
1.4
|
|
中等沖擊
|
1
|
1.1
|
1.3
|
1.4
|
1.6
|
|
強烈沖擊
|
1.1
|
1.3
|
1.4
|
1.6
|
1.9
|
|
多缸内燃機
|
均勻
|
0.8
|
0.9
|
1.1
|
1.3
|
1.4
|
|
輕度沖擊
|
1.0
|
1.1
|
1.3
|
1.4
|
1.5
|
|
中等沖擊
|
1.1
|
1.3
|
1.4
|
1.5
|
1.8
|
|
強烈沖擊
|
1.3
|
1.4
|
1.5
|
1.8
|
2
|
|
單缸内燃機
|
均勻
|
0.9
|
1.1
|
1.3
|
1.4
|
1.6
|
|
輕度沖擊
|
1.1
|
1.3
|
1.4
|
1.6
|
1.8
|
|
中等沖擊
|
1.3
|
1.4
|
1.6
|
1.8
|
2
|
|
強烈沖擊
|
1.4
|
1.6
|
1.8
|
2
|
2.3或更大
|
注:工作機(jī)工作情誤解舉(jǔ)例
均勻載荷:發電機、均勻裝料的帶(dài)式或闆式輸送機,螺旋輸送機,輕型卷揚機、包裝機械,機床進給裝置,通風機,輕型離心機,離心泵,稀液料和密度均勻物料攪拌機和混合機,按最大剪切力矩設計的沖(chōng)壓機。
輪度沖(chōng)擊:不均勻裝料的帶式或闆式輸送機,機床主傳(chuán)動裝置,重型卷揚機,起重機旋轉機構,工礦通風機,重型離心機,離心泵,粘性液料及密度不均勻物料攪拌機和混合機,多缸柱塞泵,給料泵,擠壓機,壓延機,回轉窯、鋅、鋁帶材、線材、型材軋機。
中等沖(chōng)擊:橡膠擠壓機,經常起動的橡膠和塑料混合機,輕型球磨機,木材加工機械,鋼坯初軋機,單(dān)缸活塞泵。
強烈沖擊:鏟(chǎn)鬥鏈傳動,篩傳動裝置,單鬥挖土機,重型球磨機,橡膠混煉機,冶金機械,重型給料泵,旋轉式鑽探設備(bèi),壓磚機,除鱗機,冷軋機,壓塊機。
表A2
|
每小時啓動次數
|
≤10
|
>10~60
|
>16~400
|
|
啓動頻率系數K1
|
1
|
1.1
|
1.2
|
表A3
|
小時負荷率JC,%
|
100
|
80
|
60
|
40
|
20
|
|
小時負荷率系數K2
|
1
|
0.95
|
0.88
|
0.77
|
0.6
|
注:1)

2)JC<20%時按JC=20%計
表A4
|
環境溫度,℃
|
0~10
|
>10~20
|
>20~30
|
>30~40
|
>40~50
|
|
環境溫度系數K2
|
0.89
|
1
|
1.14
|
1.33
|
1.6
|
表A5
|
冷卻方式
|
減速器
中心距a
mm
|
蝸杆轉速n1,r/min
|
|
1500
|
1000
|
750
|
500
|
|
冷卻方式系數K4
|
|
自然冷卻
(無風扇 )
|
80
|
1
|
1
|
1
|
1
|
|
100~225
|
1.37
|
1.59
|
1.59
|
<, ;, DIV align=center>1.33
|
|
250~710
|
1.51
|
1.85
|
1.89
|
1.78
|
|
風扇冷卻
|
80~710
|
1
|
A3選用示例
例:某重型卷揚機用平面二次包絡環面蝸杆減速器(帶風扇 ),電動機功率P1W=15kW,減速器佃入轉速n1=1000r/min,傳動比i=40,每日工作8h,每小時啓動15次,每次工作3min,環境溫度30℃
選用計算:由表A1查得K
A=1.3,由表A2查得K
1=1.1,則

,由表A3得K
2=0.93,由表A4查得K
3=1.14,由表A5查得K
4=1,計算輸入功率:
機械功率P1≥P1WKAK1
=15×1.3×1.1=21.45kW
熱功率P1≥P1WK2K3K4
=15×0.93×1.14×1=15.9kW
查表9選擇減速器中心距a=225mm,n1=1000r/min,i=40,額定輸入功率P1=22.8kW,可用。
附加說明:
本标準由中華(huá)人民共和國(guó)冶金工業部提出。
本标準由冶金工業部北京冶金設備(bèi)研究院歸(guī)口。
本标準由北京理工大學負責起草。首鋼總公司機械廠、上海冶金設備(bèi)總廠、西安冶金機械廠參(cān)加起草。
本标準主要起草人趙國(guó)珊、張德華、劉鳳(fèng)龍、劉文同。